Why Is My Heat Pump “Smoking” in Winter? Defrost Explained

Why Is My Heat Pump “Smoking” in Winter? Defrost Explained

If your heat pump seems to be smoking in winter, it’s almost always water vapor produced by the defrost cycle: the unit melts the frost on its outdoor coil, and this hot water evaporates into the cold air. This is normal. A burning smell, smoke inside, or loud noises are not.

Where does the frost on the outdoor unit come from?

In heating mode, the outdoor unit absorbs heat from the outside air. Its coil then becomes cooler than the air passing through it. As Natural Resources Canada explains, the humidity in the air condenses and freezes on this coil. This frost reduces heat exchange, so the unit must be cleared of it regularly.

How does defrosting work?

  1. Detection : The appliance determines when defrosting is necessary, using sensors or a timer depending on its design. Natural Resources Canada recommends “defrost on demand” settings, which only initiate the cycle when needed.
  2. Reversing the cycle : the reversing valve briefly switches the unit to cooling mode. Hot gas is then sent to the outdoor coil.
  3. Stopping the outdoor fan : the fan stops so that the heat remains on the coil.
  4. Melting : the frost melts, water flows under the appliance and some of it evaporates immediately into the cold air. This is the “smoke” you see.
  5. Back to heating : the cycle reverses again and the indoor unit starts blowing hot air again.

During these few minutes, the indoor unit usually stops blowing hot air. On some Gree models, the code H1 is displayed: the manufacturer indicates that this simply means the unit is defrosting ( Gree code guide ).

Normal or not: the table to decide

What you observe Normal ? What to do
White steam outside for a few minutes Yes Nothing
A whistling or “whoosh” sound at the beginning and end of the cycle Yes, it’s the reversal of the cycle Nothing
Outdoor fan stopped while the device is running Yes, during defrosting. Nothing
The indoor unit stops blowing for a few minutes Yes Waiting for the resumption
Water leaking under the outdoor unit Yes Check that it flows freely and does not form a block of ice.
Defrosting cycles that keep happening one after another No Call a technician
Thick ice that remains on the coil after defrosting No Call a technician
Grey smoke, burning smell, sparks No Turn off the power and call immediately.

When should we call?

Defrosting never ends

An appliance that spends all its time defrosting will not heat properly. A faulty sensor, a lack of refrigerant, or a control problem could be the cause. Note when this happens and what the appliance displays.

The ice is accumulating nonetheless

If the meltwater doesn’t drain, it refreezes under the unit and eventually rises to the coil. A unit installed too close to the ground, buried in snow, or placed under a roof overhang is often the cause. Never break the ice with a tool: the fins and tubes are easily punctured.

This is not steam

Steam dissipates quickly and has no odor. Persistent smoke, a burning or hot plastic smell, or smoke inside indicates an electrical problem: turn off the power at the circuit breaker and call a technician immediately.

How to reduce defrosting problems

  • Keep the outdoor unit elevated and clear of snow.
  • Ensure that the defrost water can drain freely under the appliance.
  • Have the defrost cycle and probes checked during fall maintenance: this is one of the points on our checklist to prepare your heat pump for winter .

If your heat pump is not heating properly between defrost cycles, consult our guide for heat pumps that are no longer heating .

Defrosting and your bill

During defrosting, the heat pump doesn’t heat the house; it uses a small amount of energy to warm its outdoor coil. The more cycles it performs, the greater the energy loss. This is yet another reason to keep the unit clean, properly adjusted, and correctly installed, and to have the defrost sensors checked during annual maintenance.

Frequently Asked Questions

Is it normal for my heat pump to smoke in winter?

Yes, in the vast majority of cases. It’s water vapor that forms during defrosting, when the frost on the external coil melts. It disappears within a few minutes.

Why does my heat pump stop heating for a few minutes?

During defrosting, the unit briefly reverses its cycle to send heat to the outdoor unit. The indoor unit then stops blowing hot air, and heating resumes.

Does defrosting consume energy?

Yes, a little, since the appliance doesn’t heat the house during the cycle. That’s why Natural Resources Canada recommends on-demand defrost controls, which limit the number of cycles.

What does H1 mean on my Gree heat pump?

According to Gree, H1 indicates that the appliance is defrosting. It is not a malfunction.

Repeated defrosting, ice that won’t melt, or a suspicious odor? Our heat pump repair service operates in Montreal, Laval, and the South Shore. Contact us or call 438-816-0992.

Need help with the process?

Talk to an HVAC MTL expert and find out which rebates you qualify for

Our specialists guide you every step of the way: from choosing your heat pump to submitting your rebate application. Get a free assessment and a personalized quote within 24 hours, with no obligation.

Your information is only used to handle your request. Privacy policy. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

We serve:

  • Montréal
  • Laval
  • Many South Shore cities

A local team based in Montréal’s Sud-Ouest, serving the whole island, Laval and the South Shore.

  • Reply within 24 hours
  • Free assessment and quote, no obligation
  • Certified technicians · RBQ 5845-4109-01